S3 Speed Sensor

Quick Overview

  • Non-contact, solid state device.
  • Tight magnetic tolerance around zero Gauss level provides 50% duty cycle.
  • Reads speeds 0 to 100 kHz.
  • Digital output signal
  • 4 to 24 VDC operation range
  • Current sinking output
  • 20ma continuous operation
  • Reverse polatiry protection
  • Temperature compensated
  • Operates from -40°C to 125°C
  • Rugged thermoplastic housing
Photos
Mechanical Drawing Preview

Price:


Price: each

Product Description

Part Number Configuration Guide

Download

Product Specifications

Magnetic
Characteristic Symbol
Limits
Min.Typ.Max.Units
Operating Point BOP 15 50 75 Gauss
Release Point BRP -75 -50 -15 Gauss
Hysteresis BHYS 30 100 150 Gauss
Maximum Field Exposure BMAX -800 800 Gauss
Active Element Depth DP 0.060 Inch
Electrical
Characteristic Symbol Test Condition
Limits
Min.Typ.Max.Units
Supply Voltage VCC Operating 4.5 24 VDC
Supply Current IS VCC = 4.5V; Output Open 4.7 8.0 mA
Output current IOUT VCC = 4.5V; Output Open 20 mA
Output Saturation Voltage VOUT(SAT) B > BOP; IOUT = 20mA 150 400 mV
Output Leakage Current IOFF B < BRP; VOUT = 24V 4.7 8.0 uA
Rise/Fall Time tr / tf RL = 1.2k; CL < 33pF 1 us
Output Definition

Recommended Pull-Up Resistor Values
Current, ISINK5V Supply12V Supply24V Supply
1.2 mA 4.3K 10.0K 20.0K
2.5 mA  2.0K 4.7K 10.0K
5.0 mA 1.0K 2.4K 4.7K
10.0 mA  510Ω  1.2K 2.4K

Output channels require customer supplied pull-up resistors unless internal pull-up option is selected.

Wiring & Connection
Standard Wiring Code
 Flying Leads
Output Blue
Gnd Black
+VCC Red

 

Wiring Option

 

 

 

Connector Options